Industry Buying is India's largest marketplace for Industrial Goods, Business Supplies, MRO Products, Tools, Equipment and many more. Wholesale Price, 7 Days Return, COD.
Welcome to our New website!
Shop By Category
Type of Product | Motor Relay |
Model No | K2CM-2MA |
Power Consumption | Before operation (50Hz): 3 VA, during operation (50Hz): 5 VA |
Contact Configuration | 1a1b |
Type of Product |
Motor Relay |
Model No |
K2CM-2MA |
Power Consumption |
Before operation (50Hz): 3 VA, during operation (50Hz): 5 VA |
Contact Configuration |
1a1b |
Mounting |
Surface mounting integrated type |
Operation Ambient Temperature |
10~+60℃ (no freezing) |
Insulation Resistance |
10 MΩ or more (between charging terminals and mounting panel) 5 MΩ or more (between charging terminals, between contact poles) |
Withstand Voltage |
Withstand voltage AC2500V (between charging terminal and mounting panel, between charging terminals) AC1000V (between contact poles) |
Shock Resistance |
294 m/s² 3 times each in X, Y, Z directions |
Monotaro ID |
46656985 |
Rated Insulation Voltage |
Motor circuit: AC500 Control power circuit: AC500 Output contact circuit: AC500 |
Range |
(Current) 2065A |
Case Color |
Munsell 5Y7/1 |
Frequency Tolerance |
95 to 105% of rated frequency |
Overload Withstand |
Main circuit: 20 times the main circuit current setting value, 2s, 2 times, 1min interval Control power supply circuit: 1.15 times the rated operating voltage, 3h, 1 time |
Operating Humidity Range |
35~85%RH |
Storage Temperature Range |
25~+65℃ |
Rated Frequency |
50/60 Hz |
Influence of Voltage |
Overload: Operating value ±5%, Operating time ±10% Phase failure: Operating value ±5%, Operating time ±10% Opposite phase: Operating value ±5%, Operating time ±10% |
Rated Working Voltage |
Motor circuit: AC200/220V, 400/440V Control power circuit: AC100/110/120V, 200/220/240V, 400/440V Output contact circuit: (contact 1a) AC120V/2A, AC240V/1A, AC440V/0.5A, DC110V/0.2A, DC220V/0.1A, (contact 1b) AC120V/5A, AC240V/2A, AC440V/1A, DC110V/0.2A, DC220V/0.1A |
Allowable Fluctuation of Voltage |
(Control power circuit) 85 to 110% of the rated operating voltage However, it should operate normally at 50% of the rated operating voltage during phase loss. |
Detection Method |
(Reverse phase detection) Current reverse phase detection |
Vibration Resistance (Destruction) |
10 ~ 25Hz 2mm double amplitude 2h for each direction of X, Y, Z |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
Omron Corporation |
Select | Quantity | Discounted price per piece(Incl. of all taxes) |
---|---|---|
2 | ₹18,423.86 | |
3 | ₹18,030.08 | |
4 | ₹17,636.30 | |
5-more | ₹16,848.73 |