Industry Buying is India's largest marketplace for Industrial Goods, Business Supplies, MRO Products, Tools, Equipment and many more. Wholesale Price, 7 Days Return, COD.
Welcome to our New website!
Shop By Category
Power Consumption | About 12 VA |
Type of Product | Thermac Neo Temperature Controller |
Input Type | Thermocouple / RTD / Current / Voltage |
Dimension | 48x96 mm |
Power Consumption |
About 12 VA |
Type of Product |
Thermac Neo Temperature Controller |
Input Type |
Thermocouple / RTD / Current / Voltage |
Dimension |
48x96 mm |
Display Type |
11-segment digital display and single emission display (7-segment display is also possible) |
Model No |
E5EN-HAA2HH03B-FLK AC100-240 |
Control Output |
Output unit method |
Indication Accuracy |
Thermocouple: (± 0.1% of indicated value or ± 1 °C, whichever is greater) ± 1 digit or less. K (-200 to 1300 °C range), T and N are -100 °C or less, and U and L are ± 2 °C ± 1 digit or less. There is no regulation for B below 400 ℃. B of 400-800 ℃ is ± 3 ℃ or less. R, S 200 °C or less is ± 3 °C ± 1 digit or less. W (± 0.3% PV or ± 3 °C, whichever is greater) ± 1 digit or less. PL II (± 0.3% PV or ± 2 °C, whichever is greater) ± 1 digit or less. Platinum resistance thermometer: (± 0.1% of indicated value or ± 0.5 °C, whichever is greater) ± 1 digit or less. Analog input: ± 0.1% FS ± 1 digit or less. CT input: ± 5% FS ± 1 digit or less. |
Display |
3-level display Contents: PV / SV / MV, PV / SV / bank No. or remaining soak time |
Sampling Cycle |
(Input) 60 ms |
Operation Ambient Temperature |
-10 to +55 ℃ (no condensation or icing) |
Function |
Manual output, heating / cooling control, loop break alarm function, SP lamp, alarm function, heater break detection function (including SSR failure, heater overcurrent detection function), 40% AT, 100% AT, manipulated variable limit, input digital filter, Self-tuning, temperature input correction, run / stop, protection, control output ON / OFF count function, square root calculation function, operation amount change rate limit, PV / SV status display function, simple program function, cooling coefficient automatic adjustment function, etc. |
Monotaro ID |
39058652 |
Power Supply Voltage |
AC 100-240 V |
Input Impedance |
Current input 150 or less, voltage input 1M or more (When connecting ES2-HB, use 1: 1 connection.) |
Case Color |
Black |
Number of Input Points |
2 (Event) |
Country of Origin |
Japan |
Number of Outputs and Type |
2 |
Pattern Setting |
Digital setting by front key or RSP input |
Character Height |
PV:11.8, SV:8.1, MV:5.8 mm |
Number of Digit |
PV and SV are 5 digits MV is 4 digits |
Optional |
Disconnection, SSR failure, and overcurrent detection function for single-phase or three-phase heaters |
Performance |
High |
Name of Manufacturer/Packer/Importer |
Omron Corporation |