Your Free Gift is Awaiting in your Inbox
Features |
|
Brand Name : | Omron |
Country of Origin : | Japan |
Shape : | General-purpose Limit switches |
Frequency : | 50/60 Hz |
Vibration Resistance : | 10 to 55 Hz, 1.5-mm double amplitude (Malfunction) |
Inrush Current : | NC: 15 A , NO: 10 A |
More Details |
-
Warranty
As per Omron's policy -
100% Original
Products -
Free Shipping
on orders above Rs. 1,000 -
Secure
Payments -
100% buyer
Protection -
EARN
IB Coins -
Non-Returnable
Features:
Load | General load |
Ratings (AC): Non-Inductive load | Rated voltage: 115 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 115 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 12 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 24 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO) Rated voltage: 115 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 12 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 24 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO) Rated voltage: 115 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO) |
Protective circuit | Classification of protection against electric shock: Class I Short-circuit protective device: 10 A fuse type gG or gI (IEC269) |
Conduit size | G1/2 |
Earth terminal | Without ground terminal |
Indicator | LED (Possible to change between Light when operating and Light when not operating.) Voltage: 115 VAC/VDC, 10 to 24 VAC/VDC |
Permissible operating frequency | Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max. |
Dielectric strength | Between each terminal of the same polarities: 600 VAC 50/60 Hz 1 min Between each terminaland ground: 1,500 VAC 50/60 Hz for 1 min Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between each terminaland ground: 2.5 kV Between each terminal and non-live-metallic part: 2.5 kV |
Mechanical durability | 10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Electrically durability | 500,000 operations min. (3 A at 250 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Shock resistance | Destruction: 1000 m/s2 max., Malfunction: 300 m/s2 max. |
Movement Differential | Standard value 7 ° max. |