Omron D4C-1501 (Inrush Current NC: 20 A, NO: 10 A Operating Force 11.77 N) General Purpose Vertical
by Omron
Features |
|
Brand Name : | Omron |
Country of Origin : | Japan |
Shape : | General-purpose Limit switches |
Frequency : | 50/60 Hz |
Operating Positions : | Standard value 15.7±1 mm |
Vibration Resistance : | 10 to 55 Hz, 1.5-mm double amplitude (Malfunction) |
More Details |
-
Warranty
As per Omron's policy -
100% Original
Products -
Free Shipping
on orders above Rs. 1,000 -
Secure
Payments -
100% buyer
Protection -
EARN
IB Coins -
7 days
Returnable
Features:
Electrical ratings | 5 A at 250 VAC, 4 A at 30 VDC |
Load | General load |
Ratings (AC) Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO) Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO) |
Ratings (AC) Inductive load | Rated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO) Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO) |
Ratings (DC) Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO) Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO) Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO) |
Ratings (DC) Inductive load | Rated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO) Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) |
Protective circuit | Classification of protection against electric shock: Class I (with earth wire) Short-circuit protective device: 10 A fuse type gI or gG (IEC60269) |
Earth terminal | With earth wire |
Cable specifications | VCTF oil-resistant cable, 3 m |
Permissible operating frequency | Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max. |
Dielectric strength | Between each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 min |
Impulse withstand voltage | Between live-metallic part and ground: 2.5 kV Between each terminal and non-live-metallic part: 2.5 kV |
Mechanical durability | 10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Electrical durability | 200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Shock resistance | Destruction: 1000 m/s2 max., Malfunction: 500 m/s2 max. |