Your Free Gift is Awaiting in your Inbox
Features |
|
Brand Name : | Omron |
Country of Origin : | Japan |
Shape : | General-purpose Limit switches |
Operating Temperature : | -40 to 100 ℃ |
Frequency : | 50/60 Hz |
Type of Product : | General Purpose Vertical Limit Switch |
More Details |
-
Warranty
As per Omron's policy -
100% Original
Products -
Free Shipping
on orders above Rs. 1,000 -
Secure
Payments -
100% buyer
Protection -
EARN
IB Coins -
Non-Returnable
Features:
Load | General load |
Contact configuration | 2-circuit double break type |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO) Rated voltage: 480 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO) Rated voltage: 600 VAC / Resistive load: 3 A(NC) 1 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) Rated voltage: 480 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO) Rated voltage: 600 VAC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1 A(NC) 0.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO) Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO) Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO) Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO) Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO) Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO) |
Protective circuit | Classification of protection against electric shock: Class I (with ground terminal) |
Conduit size | G1/2 |
Permissible operating frequency | Mechanically: 300 operations / 1 minute max., Electrically: 30 operations / 1 minute max. |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ min. Between live-metallic part and ground: 100 MΩ min. Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min Between live-metallic part and ground: 2,200 VAC 50/60 Hz 1 min Between each terminal and non-live-metallic part: 2,200 VAC 50/60 Hz 1 min |
Mechanical durability | 50,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Electrical durability | 1,000,000 operations min. (10 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH) |
Shock resistance | Destruction: 1000 m/s2 max., Malfunction: 600 m/s2 max.. |
Pre-Travel | Standard value 15 ° max. Average value 12 ° max. |
Movement Differential | Standard value 5 ° max. Average value 4 ° max. |
6,999
(GST inclusive price)
5,931
(GST extra)
2.19% OFF
|
Please enter your e-mail address and we will send you a confirmation mail to reset your password.
Your password has been reset successfully.
To sign in with your new password, Click here