Your Free Gift is Awaiting in your Inbox
Features |
|
Brand Name : | Fluke |
Type : | Earth Resistance Tester Kit |
Earth Resistance Measurement Upto : | 0.15 Ω to 2 kΩ |
Resolution : | 0.01 Ω to 1 Ω |
Dimension (mm) : | 113x54x216 mm |
Weight : | 850 g |
More Details |
-
Warranty
As per Fluke's policy -
100% Original
Products -
Free Shipping
on orders above Rs. 1,000 -
Secure
Payments -
100% buyer
Protection -
EARN
IB Coins -
7 days
Returnable
Earth Ground Tester for resistance measurement Kit
The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.
Includes :
General specifications :
Measuring functions | 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage |
---|---|
Intrinsic error | Refers to the reference temperature range and is guaranteed for one year |
Measuring rate | 2 measurements/second |
Battery[1] | One 9 volt alkaline (LR61) |
Battery condition | LO-BAT is displayed if voltage drops below 6.5 V |
Voltages | Between jacks H/C2 and E/C1: 250 Veff maximum (effective voltage) Between jacks S/P2 and E/C1: 250 Veff maximum |
Climatic class | VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) |
Temperature performance[2] |
Working: -10 °C to +50 °C (+14 °F to +122 °F) Operating: 0 °C to +35 °C (+32 °F to +95 °F) Storage: -20 °C to +60 °C (+68 °F to +140 °F) Reference: +23 °C ± 2 °C (+73 °F ± 4 °F) |
Temperature coefficient | ± 0.1 % of range per degree Kelvin |
Safety | IEC/EN 61010-1, 600 V CAT II, pollution degree 2 |
Dimensions | 113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster |
Weight | 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 |
Note: | [1]If the tester is not going to be used, or is being stored for a long period, Remove the battery and store separately from the tester to avoid damage from battery leakage. |
Note: | 2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use. |
Electrical specifications | |
Maximum deviations: | E1 Influence factor Position E1 Deviation influence 0 % E2 Influence factor Supply voltage E2 Deviation influence 0 % E3 Influence factor Temperature E3E3 Deviation influence 2.3 % E4 Influence factor Serial interference voltage (20 V) E4 Deviation influence 0.6 % E5 Influence factor Probe- and auxiliary probe resistance E5 Deviation influence 10 % |
Test voltage | 3.7 kV |
Protection type | IP 40; IEC/EN 60529 |
Electromagnetic compatibility |
Emission: IEC/EN 61326 Class B Immunity: IEC/EN 61326 Annex C |
RE resistance measurement |
Measuring method Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5 Open circuit voltage 23 to 24 V ac Short circuit current > 50 mA ac Measuring frequency 128 Hz Maximum permissible overload 250 Veff |
Measuring time | 8 seconds (average from when START is pressed) |
Limit input | Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient) |
Automatic changeover of Resolution |
RH < 7 kΩ Resolution 0.01 ΩRH < 50 kΩ Resolution 0.1 ΩRH > 50 kΩ Resolution 1 Ω |
Interference voltage display dc + ac |
Vmax 30 Veff Common mode rejection > 80 dB at 50 Hz and 60 HzRi 680 kΩ Measuring uncertainty < 10 % for pure ac and dc signals |
Measuring range | |
0.15 Ω to 20 Ω | Resolution 0.01 Ω Display range 0 to 19.99 Ω |
200 Ω | Resolution 0.1 Ω Display range 20 to 199.9 Ω |
2 kΩ | Resolution 1 Ω Display range 200 to 1999 Ω |
Intrinsic uncertainty | ± (6 % of measured value + 5D) |
Operating uncertainty IEC 61557[1] |
± (18 % of measured value + 5D) |
Notes: | [1] Covers all deviations caused by influence quantities E1-E5. If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes. Measured values are outside of the specified operating uncertainty. |
Buy Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ online in India at wholesale rates. If you have been looking for Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ dealers, your search ends here as you can get the best Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ distributors in top cities such as Delhi NCR, Mumbai, Chennai, Bengaluru, Kolkata, Chennai, Pune, Jaipur, Hyderabad and Ahmedabad. You can purchase Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ prices, you can be totally sure to get the best rates as Industrybuying brings you genuine Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ rates and quality assured products only from the best of brands with exclusive brand discounts you won’t find anywhere else. Procure Fluke 1621 Earth Resistance Tester Kit 0.15 Ω to 2 kΩ today and avail the best offers on your purchase.